The CS-1600 system combines the reliable, proven mechanics of the former CA-1500 model with the advanced CS-series technology in a compact analyser.
It is ideal for mid-sized laboratories requiring an easy-to-use, cap-piercing analyser capable of running clotting, chromogenic, and immunologic assays simultaneously.

CS 1600
CS 1600
  • maingate-bulletpoint-100x100-1.svg
    Fully automated haemostasis benchtop analyser offering high functionality in an easy-to-use and compact size model.
  • maingate-bulletpoint-100x100-1.svg
    It features multi-wavelength technology with three different detection technologies: clotting, chromogenic and immunological (turbidimetric).

Consistent accuracy and reliability:Sysmex proprietary multi-wavelength analysis technology automatically uses optimal wavelength for each measurement parameter to reduce effects of interfering substances on the absorbance spectra or in specific sample conditions such as low fibrinogen level or severe lipaemia to deliver accurate result on every test run. Primary sample volume is checked before analysis. Results are flagged if incorrect anticoagulant to blood sample ratio is suspected to ensure only reliable results are reported by laboratories.

Operational efficiency: Intuitive cap-piercing technology on the CS-1600 system allows a mix of capped and uncapped tubes and cups on the same rack and reduces sample processing time. STAT samples can be analyzed as priority by executing either sample or rack interruption for greater efficiency. Onboard reagent status information provides an alert to Medical Technologist to add or replace any reagent based on the remaining volume or number of tests level. When the reagent onboard stability time has passed, Medical Technologist will also be alerted via an audio alarm. After routine analyser shut-down, an automatic wake-up function will wake the machine for the new day’s routine so Medical Technologists can start work almost immediately once they arrive at the laboratory. Handover lists can be generated to facilitate a smooth handover for shift changes.

The CS-1600 System automatically take cares of the data preservation for laboratories by performing auto backup function at scheduled timings or at before routine shutdown.

Support laboratory accreditation requirements and documentation:Traceability info/operation log allow laboratories to trace the measurement results and the related information such as the reagent lot number, calibration curve used in testing, and the most recent date and time of QC measurement. The operation log provides an audit trail of the operation, maintenance history and any setting changes in the system.

  • PT: Dade Innovin, Thromborel S
  • APTT: Dade Actin, Dade Actin FS, Dade Actin FSL, Pathromtin SL
  • Fibrinogen: Dade Thrombin, Dade Fibrinogen Determination Reagent
  • Thrombin Time: Test Thrombin, Thromboclotin
  • Batroxobin Time: Batroxobin
  • Factor Deficiency: Factor II, V, VII, VIII, IX, X, XI, XII
  • Lupus Anticoagulant: LA1 Screen, LA2 Confirmation
  • Protein C Pathway: ProC Global, Protein C Reagent, Berichrom Protein C, Protein S Ac, Innovance Free Protein S Antigen
  • Antithrombin: Innovance Antithrombin, Berichrom Antithrombin III (A)
  • D-Dimer: Innovance D-Dimer
  • Von Willebrand Factor: vWF Ag, Innovance vWF Ac
  • Chromogenic: Factor VIII Chromogenic, Berichrom C-1 Inhibitor, Berichrom α2-Antiplasmin, Berichrom Plasminogen
Detection principles:
  • Multi-wavelength detector for transmitted light at 405, 575, 660 and 800 nm
Detection channel/method:
  • 8 channels for clotting, chromogenic and immunoassays
Parameters:
  • 20 parameters can be analyzed simultaneously
Throughput:
  • PT: 120 tests/h
  • PT/APTT: 110 tests/h
Sampling:
  • Continuous loading of maximum 5 racks of 10 tubes each, cap-piercing functionality
  • STAT sample can be analyzed as priority by executing either sample or rack interruption function
Reagent holder:
  • 28 reagent vial positions (15°C), of these 12 positions are tilted at 10°
  • 5 positions (room temperature)
Reference curves:
  • Maximum 5 reference curves per lot
  • Maximum 5 lots per parameter
Quality control:
  • X-bar control, Levy-Jennings control
  • Multi-rule (Westgard Rule) monitoring
  • 40 files with maximum 300 data points each
Data storage:
  • Up to 3,000 sample results with reaction curves
Printer:
  • Graphic or Data Printer (optional)
Dimensions (WxHxD)/weights:
Main unit:
  • 760 × 540 × 690 mm, 85 kg (approximate)
CS 1600

MainGate Offerings

Pioneer in in vitro diagnostic solutions
  • Sole representatives of Sysmex in Sri Lanka
  • Experienced staff at your service
  • World leading product offering
  • Solutions that meet your requirements
  • Reduced Total Cost of ownership
  • Technology Leadership